HW-FS-01 flowmeter parameters | |
Material | Housing: Aluminum |
Gear: alloy | |
seal | MVQ(Silicone rubber "O" ring) |
temperature range | -10℃~+80℃ |
Accuracy level | ±0.5% |
Repeatability | ±0.5% |
Pressure range | Max 2MPa |
Installation method | Horizontal installation |
Dimensions | 59*78*89mm |
Power supply | 12VDC |
Maximum current output | 25mA |
Thread | G1/8 |
Flow range | 8~600(ml/min) |
Meter factor | 9000 |